					型號(hào) 
				 | 
				
					AX 501 
				 | 
				
					AX 502 
				 | 
				
					AX 503 
				 | 
			
			
				| 
					 
					
 
				 | 
				
					
				 | 
				
					Lineal 
				 | 
				
					Lineal 
				 | 
			
			
				| 
					
				 | 
				
					
				 | 
				
					2 
				 | 
				
					3 
				 | 
			
			
				
					Voltage control 
				 | 
				
					 
						Output 1:0 to 30 VDC 
					 
					
						Display resolution:100 mV 
					 
					
						Basic accuracy:± 0.5 % of reading + 1D 
					 
					
						Residual ripple:< 1 mV RMS 
					 
				 | 
				
					 
						Output 1:0 to 30 VDC 
					 
					
						Output 2:0 to 30 VDC 
					 
					
						Display resolution:100 mV 
					 
					
						Basic accuracy:± 0.5 % of reading + 1D 
					 
					
						Residual ripple:< 1 mV RMS 
					 
				 | 
				
					 
						Output 1:0 to 30 VDC 
					 
					
						Output 2:0 to 30 VDC 
					 
					
						Display resolution:100 mV 
					 
					
						Basic accuracy:± 0.5 % of reading + 1D 
					 
					
						Residual ripple:< 1 mV RMS 
					 
					
						Output 3:3 and 5 VDC (2.7 to 5.5 VDC) 
					 
				 | 
			
			
				
					Horizontal deflection 
				 | 
				
					 
						Output 1:0 to 2.5 A 
					 
					
						Resolution:100 mA 
					 
					
						Basic accuracy:± 0.5 % of reading + 1D  
					 
					
						Indication of limitation:LED channel 1 
					 
					
						Short-circuit protection:Electronic current limitation 
					 
					
						Overheating protection:Temperature control 
					 
				 | 
				
					 
						Output 1:0 to 2.5 A 
					 
					
						Output 2:0 to 2.5 A 
					 
					
						Resolution:100 mA 
					 
					
						Basic accuracy:± 0.5 % of reading + 1D  
					 
					
						Indication of limitation:LED channels 1 and 2 
					 
					
						Short-circuit protection:Electronic current limitation 
					 
					
						Overheating protection:Temperature control 
					 
				 | 
				
					 
						Output 1:0 to 2.5 A 
					 
					
						Output 2:0 to 2.5 A 
					 
					
						Resolution:100 mA 
					 
					
						Basic accuracy:± 0.5 % of reading + 1D  
					 
					
						Output 3:0 to 5 A 
					 
					
						Indication of limitation:LED channels 1, 2 and 3 
					 
					
						Short-circuit protection:Electronic current limitation 
					 
					
						Overheating protection:Temperature control 
					 
				 | 
			
			
				
					Coupling of outputs 
				 | 
				
					-- 
				 | 
				
					 
						Tracking:Output 1 master,Output 2 slave 
					 
					
						Series mode:0 to 60 VDC / 0 to 2.5 A 
					 
					
						Parallel mode:0 to 30 VDC / 0 to 5 A 
					 
				 | 
				
					 
						Tracking:Output 1 master,Output 2 slave 
					 
					
						Series mode:0 to 60 VDC / 0 to 2.5 A 
					 
					
						Parallel mode:0 to 30 VDC / 0 to 5 A 
					 
				 | 
			
			
				
					Stability in the event of variations 
				 | 
				
					 
						Mains ± 10 %:± 0.03 % of reading + 2 mV 
					 
					
						Load from 0 to 100 %:± 0.02 %of reading + 5 mV 
					 
				 | 
				
					 
						 
					 
					
						Mains ± 10 %:± 0.03 % of reading + 2 mV 
					 
					
						Load from 0 to 100 %:± 0.02 %of reading + 5 mV 
					 
					
						 
					 
				 | 
				
					 
						Mains ± 10 %:± 0.03 % of reading + 2 mV 
					 
					
						Load from 0 to 100 %:± 0.02 %of reading + 5 mV 
					 
					
						Mains ± 10 % (Output 3):± 4 mV 
					 
					
						Load from 0 to 100 % (Output 3):± 20 mV 
					 
				 | 
			
			
				
					Display 
				 | 
				
					 
						3 digits – green LEDs 
					 
					
						Simultaneous U and I 
					 
				 | 
				
					 
						 
					 
					
						3 digits – green LEDs 
					 
					
						Simultaneous U and I / Outputs 1 and 2 
					 
					
						 
					 
				 | 
				
					 
						3 digits – green LEDs 
					 
					
						Simultaneous U and I / Outputs 1 and 2 
					 
				 | 
			
			
				
					Coarse and fine adjustment 
				 | 
				
					Outputs 1 
				 | 
				
					Outputs 1 and 2 
				 | 
				
					Outputs 1 and 2 
				 | 
			
			
				
					Connections 
				 | 
				
					 
						Double-well safety terminals 
					 
					
						Yellow/green male earth safety connection 
					 
				 | 
				
					 
						Double-well safety terminals 
					 
					
						Yellow/green male earth safety connection 
					 
				 | 
				
					 
						Double-well safety terminals 
					 
					
						Yellow/green male earth safety connection 
					 
				 | 
			
			
				
					Reference temperature 
				 | 
				
					23 °C ± 5 °C 
				 | 
				
					23 °C ± 5 °C 
				 | 
				
					23 °C ± 5 °C 
				 | 
			
			
				
					Operating temperature 
				 | 
				
					0 to 50 °C 
				 | 
				
					0 to 50 °C 
				 | 
				
					0 to 50 °C 
				 | 
			
			
				
					Power supply 
				 | 
				
					 
						110 VAC ± 10 % / 60 Hz 
					 
					
						230 VAC ± 10 % / 50 Hz 
					 
				 | 
				
					 
						110 VAC ± 10 % / 60 Hz 
					 
					
						230 VAC ± 10 % / 50 Hz 
					 
				 | 
				
					 
						110 VAC ± 10 % / 60 Hz 
					 
					
						230 VAC ± 10 % / 50 Hz 
					 
				 | 
			
			
				
					Dimensions (L x H x W) 
				 | 
				
					225 x 120 x 270 mm 
				 | 
				
					225 x 120 x 270 mm 
				 | 
				
					225 x 120 x 270 mm 
				 | 
			
			
				
					Weight 
				 | 
				
					4 kg 
				 | 
				
					4.5 kg 
				 | 
				
					6 kg 
				 | 
			
			
				
					Safety 
				 | 
				
					 
						IEC 61010 - Class 1 - Pol. 2 
					 
					
						Output: Cat. I, 100 V 
					 
					
						Mains power supply: Cat. II, 300 V 
					 
				 | 
				
					 
						IEC 61010 - Class 1 - Pol. 2 
					 
					
						Output: Cat. I, 100 V 
					 
					
						Mains power supply: Cat. II, 300 V 
					 
				 | 
				
					 
						IEC 61010 - Class 1 - Pol. 2 
					 
					
						Output: Cat. I, 100 V 
					 
					
						Mains power supply: Cat. II, 300 V 
					 
				 | 
			
			
				
					Warranty 
				 | 
				
					3 years 
				 | 
				
					3 years 
				 | 
				
					3 years 
				 |